Governor Model: GPWSCC

 

Model Equations and/or Block Diagrams

   

Parameters:

MWCap Turbine Rating, MW
Pmax Maximum gate opening, pu of mwcap
Pmin Minimum gate opening, pu of mwcap
R Governor control flag
Td Input filter time constant, sec
Tf Washout time constant, sec
Tp Gate servo time constant, sec
Velopen Maximum gate opening velocity, pu/sec
Velclose Maximum gate closing velocity, pu/sec
Kp Proportional gain, pu
Kd Derivative gain, pu
Ki Integral gain, pu
Kg Gate servo gain, pu
Tturb Turbine time constant, sec
Aturb Turbine numerator multiplier
Bturb Turbine denominator multiplier
Tt Power feedback time constant, sec
db1 Intentional deadband width, Hz
Eps Unintentional db hysteresis, Hz
db2 Unintentional deadband, MW
Gv1 Nonlinear gain point 1, pu gv
Pgv1 Nonlinear gain point 1, pu power
Gv2 Nonlinear gain point 2, pu gv
Pgv2 Nonlinear gain point 2, pu power
Gv3 Nonlinear gain point 3, pu gv
Pgv3 Nonlinear gain point 3, pu power
Gv4 Nonlinear gain point 4, pu gv
Pgv4 Nonlinear gain point 4, pu power
Gv5 Nonlinear gain point 5, pu gv
Pgv5 Nonlinear gain point 5, pu power
Gv6 Nonlinear gain point 6, pu gv
Pgv6 Nonlinear gain point 6, pu power